; DELTA ELECTRONIC, INC. ; Network: CANopen ; Modlue: ; Device: ; Model: ; Create by EDS Builder software [FileInfo] FileName=MD810-CANOpen-INV V3.3.eds FileVersion=3 FileRevision=0 EDSVersion=5.0 Description=MD810 INV Module V3.3 CreationTime=02:11PM CreationDate=05-31-2017 CreatedBy=1970 ModificationTime=02:11PM ModificationDate=05-31-2017 ModifiedBy=1970 [DeviceInfo] VendorName=Shenzhen Inovance Technology Co., Ltd VendorNumber=0x000003B9 ProductName=MD810 INV_V3.3 ProductNumber=0x000B0112 RevisionNumber=0x00000001 OrderCode=0 BaudRate_10=0 BaudRate_20=1 BaudRate_50=1 BaudRate_125=1 BaudRate_250=1 BaudRate_500=1 BaudRate_800=0 BaudRate_1000=1 SimpleBootUpMaster=0 SimpleBootUpSlave=1 Granularity=0x08 DynamicChannelsSupported=0 GroupMessaging=0 NrOfRXPDO=4 NrOfTXPDO=4 LSS_Supported=0 [DummyUsage] Dummy0001=0 Dummy0002=0 Dummy0003=0 Dummy0004=0 Dummy0005=0 Dummy0006=0 Dummy0007=0 [Comments] Lines=0 [MandatoryObjects] SupportedObjects=3 1=0x1000 2=0x1001 3=0x1018 [1000] ParameterName=Device type ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=0x10000 PDOMapping=0 [1001] ParameterName=Error register ObjectType=7 DataType=0x0005 AccessType=ro PDOMapping=0 [1018] ParameterName=Identity Object ObjectType=9 SubNumber=5 [1018sub0] ParameterName=number of entries ObjectType=7 DataType=0x0005 AccessType=ro LowLimit=1 HighLimit=4 DefaultValue=4 PDOMapping=0 [1018sub1] ParameterName=Vendor ID ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=0x000003B9 PDOMapping=0 [1018sub2] ParameterName=Product code ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=0x000B0112 PDOMapping=0 [1018sub3] ParameterName=Revision number ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=0x00000001 PDOMapping=0 [1018sub4] ParameterName=Serial number ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=0x00010000 PDOMapping=0 [OptionalObjects] SupportedObjects=25 1=0x1003 2=0x1005 3=0x1008 4=0x100C 5=0x100D 6=0x1014 7=0x1016 8=0x1017 9=0x1200 10=0x1400 11=0x1401 12=0x1402 13=0x1403 14=0x1600 15=0x1601 16=0x1602 17=0x1603 18=0x1800 19=0x1801 20=0x1802 21=0x1803 22=0x1A00 23=0x1A01 24=0x1A02 25=0x1A03 [1003] ParameterName=Predefined error field ObjectType=8 SubNumber=3 [1003sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=0 PDOMapping=0 [1003sub1] ParameterName=standard error field1 ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=0 PDOMapping=0 [1003sub2] ParameterName=standard error field2 ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=0 PDOMapping=0 [1005] ParameterName=COB-ID SYNC message ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0x80 PDOMapping=0 [1008] ParameterName=Manufacturer Device Name ObjectType=7 DataType=0x0009 AccessType=const DefaultValue=M810 PDOMapping=0 [100C] ParameterName=Guard time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [100D] ParameterName=Life time factor ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=0 PDOMapping=0 [1014] ParameterName=COB-ID EMCY message ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0x80 PDOMapping=0 [1016] ParameterName=consumer heartbeat time ObjectType=8 SubNumber=4 [1016sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 [1016sub1] ParameterName=consumer heartbeat time ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [1016sub2] ParameterName=consumer heartbeat time ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [1016sub3] ParameterName=consumer heartbeat time ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [1017] ParameterName=Producer heartbeat time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1200] ParameterName=Server SDO parameter ObjectType=9 SubNumber=3 [1200sub0] ParameterName=Number of supported entries ObjectType=7 DataType=0x0005 AccessType=ro LowLimit=2 HighLimit=2 DefaultValue=2 PDOMapping=0 [1200sub1] ParameterName=COB-ID Client -> Server (rx) ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=$NODEID+0x600 PDOMapping=0 [1200sub2] ParameterName=COB-ID Server -> Client (tx) ObjectType=7 DataType=0x0007 AccessType=ro DefaultValue=$NODEID+0x580 PDOMapping=0 [1400] ParameterName=1st Receive PDO ObjectType=9 SubNumber=4 [1400sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 [1400sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NodeID+0x200 PDOMapping=0 [1400sub2] ParameterName=Transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1400sub3] ParameterName=Inhibit timer ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1401] ParameterName=2nd receive PDO ObjectType=9 SubNumber=4 [1401sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 [1401sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0x80000300 PDOMapping=0 [1401sub2] ParameterName=Transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1401sub3] ParameterName=inhibit time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1402] ParameterName=3rd receive PDO ObjectType=9 SubNumber=4 [1402sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 [1402sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0x80000400 PDOMapping=0 [1402sub2] ParameterName=Transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1402sub3] ParameterName=inhibit time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1403] ParameterName=4th receive PDO ObjectType=9 SubNumber=4 [1403sub0] ParameterName=number of entries ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 [1403sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0x80000500 PDOMapping=0 [1403sub2] ParameterName=Transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1403sub3] ParameterName=inhibit time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1600] ParameterName=1st receive PDO mapping ObjectType=9 SubNumber=3 [1600sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=2 PDOMapping=0 [1600sub1] ParameterName=RPDO1 1st parameter ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0x20731210 PDOMapping=0 [1600sub2] ParameterName=RPDO1 2nd parameter ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0x20731110 PDOMapping=0 [1601] ParameterName=2st receive PDO mapping ObjectType=9 SubNumber=1 [1601sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=0 PDOMapping=0 [1602] ParameterName=3rd receive PDO mapping ObjectType=9 SubNumber=1 [1602sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=0 PDOMapping=0 [1603] ParameterName=4th receive PDO mapping ObjectType=9 SubNumber=1 [1603sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=0 PDOMapping=0 [1800] ParameterName=1st transmit PDO ObjectType=9 SubNumber=6 [1800sub0] ParameterName=largest sub-index supported ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 [1800sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0x40000180 PDOMapping=0 [1800sub2] ParameterName=transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1800sub3] ParameterName=inhibit time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=300 PDOMapping=0 [1800sub4] ParameterName=reserved ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=0 PDOMapping=0 [1800sub5] ParameterName=event timer ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=1000 PDOMapping=0 [1801] ParameterName=2nd transmit PDO ObjectType=9 SubNumber=6 [1801sub0] ParameterName=largest sub-index supported ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 [1801sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0xC0000280 PDOMapping=0 [1801sub2] ParameterName=transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1801sub3] ParameterName=inhibit time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=300 PDOMapping=0 [1801sub4] ParameterName=reserved ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=0 PDOMapping=0 [1801sub5] ParameterName=event timer ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=1000 PDOMapping=0 [1802] ParameterName=3rd transmit PDO ObjectType=9 SubNumber=6 [1802sub0] ParameterName=largest sub-index supported ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 [1802sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0xC0000380 PDOMapping=0 [1802sub2] ParameterName=transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1802sub3] ParameterName=inhibit time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=300 PDOMapping=0 [1802sub4] ParameterName=reserved ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=0 PDOMapping=0 [1802sub5] ParameterName=event timer ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=1000 PDOMapping=0 [1803] ParameterName=4th transmit PDO ObjectType=9 SubNumber=6 [1803sub0] ParameterName=number of entries ObjectType=7 DataType=0x0005 AccessType=ro LowLimit=2 HighLimit=5 DefaultValue=5 PDOMapping=0 [1803sub1] ParameterName=COB-ID ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=$NODEID+0xC0000480 PDOMapping=0 [1803sub2] ParameterName=transmission type ObjectType=7 DataType=0x0005 AccessType=rw DefaultValue=255 PDOMapping=0 [1803sub3] ParameterName=inhibit time ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=300 PDOMapping=0 [1803sub4] ParameterName=reserved ObjectType=7 DataType=0x0005 AccessType=rw PDOMapping=0 [1803sub5] ParameterName=event timer ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=1000 PDOMapping=0 [1A00] ParameterName=1st transmit PDO mapping ObjectType=9 SubNumber=3 [1A00sub0] ParameterName=number of mapped application objects ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=2 PDOMapping=0 [1A00sub1] ParameterName=TPDO1 1st parameter ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0x20704510 PDOMapping=0 [1A00sub2] ParameterName=TPDO1 2nd parametera ObjectType=7 DataType=0x0007 AccessType=rw DefaultValue=0x20704610 PDOMapping=0 [1A01] ParameterName=2nd transmit PDO mapping ObjectType=9 SubNumber=1 [1A01sub0] ParameterName=number of mapped application objects ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=0 PDOMapping=0 [1A02] ParameterName=3rd transmit PDO mapping ObjectType=9 SubNumber=1 [1A02sub0] ParameterName=number of mapped application objects ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=0 PDOMapping=0 [1A03] ParameterName=4th transmit PDO mapping ObjectType=9 SubNumber=1 [1A03sub0] ParameterName=number of mapped application objects ObjectType=7 DataType=0x0005 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=0 PDOMapping=0 [ManufacturerObjects] SupportedObjects=22 1=0x2070 2=0x2073 3=0x20A0 4=0x20A1 5=0x20A5 6=0x20A6 7=0x20A8 8=0x20A9 9=0x20F0 10=0x20F1 11=0x20F2 12=0x20F3 13=0x20F4 14=0x20F5 15=0x20F6 16=0x20F7 17=0x20F8 18=0x20F9 19=0x20FA 20=0x20FB 21=0x20FC 22=0x20FD [2070] ParameterName=Monitoring Disp ObjectType=9 SubNumber=66 [2070sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x50 PDOMapping=0 [2070sub1] ParameterName=Running Frequency ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub2] ParameterName=Frequecny Reference ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub3] ParameterName=Bus Voltage ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub4] ParameterName=Output Voltage ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub5] ParameterName=Output Current ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub6] ParameterName=Output Power ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub7] ParameterName=Output Torque ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub8] ParameterName=DI State ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub9] ParameterName=DO State ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070subA] ParameterName=AI1 Voltage ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070subB] ParameterName=AI2 Voltage ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070subC] ParameterName=Motor Speed ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070subD] ParameterName=Count Value ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070subE] ParameterName=Length Value ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070subF] ParameterName=Load Speed Display ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub10] ParameterName=PID Setting ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub11] ParameterName=PID Feedback ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub12] ParameterName=PLC Stage ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub13] ParameterName=Pulse Frequency ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub14] ParameterName=Feedback Speed ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub15] ParameterName=Remaining Running Time ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub16] ParameterName=AI1 Voltage Before Emendation ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub17] ParameterName=AI2 Voltage Before Emendation ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub18] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=0 [2070sub19] ParameterName=Linear Speed ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub1A] ParameterName=Accumulative Power-on Time ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub1B] ParameterName=Accumulative Running Time ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub1C] ParameterName=Pulse Input Frequency ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub1D] ParameterName=Communication Setting Value ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub1E] ParameterName=Encoder Feedback Speed ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub1F] ParameterName=Main Frequency X ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub20] ParameterName=Auxiliary Frequency Y ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub21] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=0 [2070sub22] ParameterName=Sync Motor Rotor Position ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub23] ParameterName=Motor Temperature ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub24] ParameterName=Target Torque ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub25] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=0 [2070sub26] ParameterName=Power Factor Angle ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub27] ParameterName=ABZ Position ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub28] ParameterName=Target Voltage upon V/F Separation ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub29] ParameterName=Output Voltage upon V/F Separation ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub2A] ParameterName=DI State Visual Display ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub2B] ParameterName=DO State Visual Display ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub2C] ParameterName=DI Func State Visual Display 1 ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub2D] ParameterName=DI Func State Visual Display 2 ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub2E] ParameterName=Fault Subcode ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub2F] ParameterName=Invertor Temperature ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub30] ParameterName=Voltage before PTC Correction ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub31] ParameterName=Voltage after PTC Correction ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub32] ParameterName=Pulses for Position Lock Deviation ObjectType=7 DataType=0x0003 AccessType=ro PDOMapping=1 [2070sub3B] ParameterName=Phase Z Counrting ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub3C] ParameterName=Current Set Frq ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub3D] ParameterName=Current Running Frq ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub3E] ParameterName=AC Drive Running State ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub3F] ParameterName=Current Fault Code ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub40] ParameterName=Sent Val of P-P Communication ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub41] ParameterName=Recv Val of P-P Communication ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub42] ParameterName=Torque Upper Limit ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub45] ParameterName=Inverter State ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub46] ParameterName=Output Frq ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub47] ParameterName=Motor Speed ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub48] ParameterName=Eletric Current ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub49] ParameterName=CardStatus ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub4F] ParameterName=Converter Reference Current ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2070sub50] ParameterName=Converter Power ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=1 [2073] ParameterName=Control Para ObjectType=9 SubNumber=9 [2073sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=26 PDOMapping=0 [2073sub11] ParameterName=Written Freq ObjectType=7 DataType=0x0003 AccessType=wo PDOMapping=1 [2073sub12] ParameterName=Control Command ObjectType=7 DataType=0x0006 AccessType=wo PDOMapping=1 [2073sub13] ParameterName=DO ObjectType=7 DataType=0x0006 AccessType=wo PDOMapping=1 [2073sub14] ParameterName=A01 ObjectType=7 DataType=0x0006 AccessType=wo PDOMapping=1 [2073sub15] ParameterName=A02 ObjectType=7 DataType=0x0006 AccessType=wo PDOMapping=1 [2073sub16] ParameterName=FMP ObjectType=7 DataType=0x0006 AccessType=wo PDOMapping=1 [2073sub18] ParameterName=The Speed Instruction ObjectType=7 DataType=0x0003 AccessType=wo PDOMapping=1 [2073sub1A] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=0 [20A0] ParameterName=Torque Ctrl ObjectType=9 SubNumber=14 [20A0sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x0F PDOMapping=0 [20A0sub1] ParameterName=Speed/Torque Ctrl Sel ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20A0sub2] ParameterName=The Setting Source of Torque Ctrl ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=7 DefaultValue=0 PDOMapping=1 [20A0sub4] ParameterName=Torque Setting Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-2000 HighLimit=2000 DefaultValue=1000 PDOMapping=1 [20A0sub5] ParameterName=Filtering Time of Torque Ctrl ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=5000 DefaultValue=0 PDOMapping=1 [20A0sub6] ParameterName=Speed Limit Setting ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1200 HighLimit=1200 DefaultValue=0 PDOMapping=1 [20A0sub8] ParameterName=Acceleration Time(Torque) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=100 PDOMapping=1 [20A0sub9] ParameterName=Deceleration Time(Torque) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=100 PDOMapping=1 [20A0subA] ParameterName=The Setting Source of Speed Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20A0subB] ParameterName=Value of Speed Limit Bias ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=500 PDOMapping=1 [20A0subC] ParameterName=Way of Speed Limit Bias ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20A0subD] ParameterName=Acceleration Time(Frequency) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=10 PDOMapping=1 [20A0subE] ParameterName=Deceleration Time(Frequency) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=10 PDOMapping=1 [20A0subF] ParameterName=Switch of Torque Ctrl ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=1 PDOMapping=1 [20A1] ParameterName=VD1/VDO ObjectType=9 SubNumber=11 [20A1sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x0b PDOMapping=0 [20A1sub1] ParameterName=VDI1 Func Selc ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=0 PDOMapping=1 [20A1sub2] ParameterName=VDI2 Func Selc ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=0 PDOMapping=1 [20A1sub3] ParameterName=VDI3 Func Selc ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=0 PDOMapping=1 [20A1sub4] ParameterName=VDI4 Func Selc ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=0 PDOMapping=1 [20A1sub5] ParameterName=VDI5 Func Selc ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=0 PDOMapping=1 [20A1sub6] ParameterName=VDI State Setting Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=22222 DefaultValue=0 PDOMapping=1 [20A1sub7] ParameterName=VDI State Selc ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=11111 DefaultValue=0 PDOMapping=1 [20A1sub8] ParameterName=Func Selc For AI1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=0 PDOMapping=1 [20A1sub9] ParameterName=Func Selc For AI2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=0 PDOMapping=1 [20A1subB] ParameterName=State Selc For AI ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=111 DefaultValue=0 PDOMapping=1 [20A5] ParameterName=Control Optimization Parameter ObjectType=9 SubNumber=10 [20A5sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=23 PDOMapping=0 [20A5sub1] ParameterName=DPWM Switchover Frequency Upper Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=1200 PDOMapping=1 [20A5sub2] ParameterName=PWM Modulation Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20A5sub3] ParameterName=Dead Zone Compensation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20A5sub4] ParameterName=Random PWM Depth ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10 DefaultValue=0 PDOMapping=1 [20A5sub5] ParameterName=Fast Current Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20A5sub6] ParameterName=Sampling Delay ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=13 DefaultValue=5 PDOMapping=1 [20A5sub7] ParameterName=Undervoltage Threshold ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=600 HighLimit=1400 DefaultValue=1000 PDOMapping=1 [20A5sub8] ParameterName=SVC Optimization Parameter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=1 PDOMapping=1 [20A5sub17] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=0 [20A6] ParameterName=AI Curve Setting ObjectType=9 SubNumber=31 [20A6sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=30 PDOMapping=0 [20A6sub1] ParameterName=AI Curve 4 Minimum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=32767 DefaultValue=0 PDOMapping=1 [20A6sub2] ParameterName=Correspongding Percentage of AI Curve 4 Minimum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20A6sub3] ParameterName=AI Curve 4 Inflexion 1 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-32768 HighLimit=32767 DefaultValue=300 PDOMapping=1 [20A6sub4] ParameterName=Corresponding Percentage of AI Curve 4 Inflexion 1 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=300 PDOMapping=1 [20A6sub5] ParameterName=AI Curve 4 Inflexion 2 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-32768 HighLimit=32767 DefaultValue=600 PDOMapping=1 [20A6sub6] ParameterName=Corresponding Percentage of AI Curve 4 Inflexion 2 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=600 PDOMapping=1 [20A6sub7] ParameterName=AI Curve 4 Maximum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-32768 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20A6sub8] ParameterName=Corresponding Percentage of AI Curve 4 Maximum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20A6sub9] ParameterName=AI Curve 5 Minimum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=32767 DefaultValue=-1000 PDOMapping=1 [20A6subA] ParameterName=Corresponding Percentage of AI Curve 5 Minimum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=-1000 PDOMapping=1 [20A6subB] ParameterName=AI Curve 5 Inflexion 1 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-32768 HighLimit=32767 DefaultValue=-300 PDOMapping=1 [20A6subC] ParameterName=Corresponding Percentage of Ai Curve 5 Inflexion 1 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=-300 PDOMapping=1 [20A6subD] ParameterName=AI Curve 5 Inflexion 2 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-32768 HighLimit=32767 DefaultValue=300 PDOMapping=1 [20A6subE] ParameterName=Corresponding Percentage of AI Curve 5 Inflexion 2 Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=300 PDOMapping=1 [20A6subF] ParameterName=AI Curve 5 Maximum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-32768 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20A6sub10] ParameterName=Corresponding Percentage of AI Curve 5 Maximum Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20A6sub11] ParameterName=element 17 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub12] ParameterName=element 18 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub13] ParameterName=element 19 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub14] ParameterName=element 20 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub15] ParameterName=element 21 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub16] ParameterName=element 22 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub17] ParameterName=element 23 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub18] ParameterName=element 24 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub19] ParameterName=Jump Point of AI1 Input Corresponding Percentage ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20A6sub1A] ParameterName=Jump Amplitude of AI1 Input Corresponding Percentage ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=5 PDOMapping=1 [20A6sub1B] ParameterName=Jump Point of AI2 Input Corresponding Percentage ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20A6sub1C] ParameterName=Jump Amplitude of AI2 Input Corresponding Percentage ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=5 PDOMapping=1 [20A6sub1D] ParameterName=element 29 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A6sub1E] ParameterName=element 30 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8] ParameterName=Synchronization Control ObjectType=9 SubNumber=101 [20A8sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=100 PDOMapping=0 [20A8sub1] ParameterName=Local Address ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=124 DefaultValue=1 PDOMapping=1 [20A8sub2] ParameterName=Baud Rate ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=5 HighLimit=6 DefaultValue=6 PDOMapping=1 [20A8sub3] ParameterName=Synchronization Control Communication Timeout Duration ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=10 PDOMapping=1 [20A8sub4] ParameterName=element 4 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub5] ParameterName=element 5 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub6] ParameterName=element 6 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub7] ParameterName=element 7 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub8] ParameterName=element 8 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub9] ParameterName=element 9 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8subA] ParameterName=element 10 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8subB] ParameterName=Master/Slave Selection in Speed and Position Control ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20A8subC] ParameterName=Synchronization Mode Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20A8subD] ParameterName=Station Number to Master to be Followed(set for slave) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=124 DefaultValue=1 PDOMapping=1 [20A8subE] ParameterName=element 14 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8subF] ParameterName=Slave Configuration Parameter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20A8sub10] ParameterName=Acceleration Time(Slave) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20A8sub11] ParameterName=Deceleration Time(Slave) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20A8sub12] ParameterName=Electronic Gear Ratio(Numerator) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1 PDOMapping=1 [20A8sub13] ParameterName=Electronic Gear Ratio(Denominator) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1 PDOMapping=1 [20A8sub14] ParameterName=Speed Feedforward Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1200 DefaultValue=1000 PDOMapping=1 [20A8sub15] ParameterName=Position Loop Proportional Gain Switchover Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=1 PDOMapping=1 [20A8sub16] ParameterName=Speed Loop Proportional Gain 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=500 PDOMapping=1 [20A8sub17] ParameterName=Deviation 1 for Position Loop Proportional Gain Switchover ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5 PDOMapping=1 [20A8sub18] ParameterName=Speed Loop Proportional Gain 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=1500 PDOMapping=1 [20A8sub19] ParameterName=Deviation 2 for Position Loope Proportional Gain Switchover ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=20 PDOMapping=1 [20A8sub1A] ParameterName=element 26 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub1B] ParameterName=Speed Filter Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=30 PDOMapping=1 [20A8sub1C] ParameterName=Acceleration Rate Compensation Coefficient ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=500 PDOMapping=1 [20A8sub1D] ParameterName=Acceleration Rate Moving Average Filter Coefficient ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=0 PDOMapping=1 [20A8sub1E] ParameterName=Minimum Pulse Deviation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=500 DefaultValue=10 PDOMapping=1 [20A8sub1F] ParameterName=Maximum Pulse Deviation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=500 PDOMapping=1 [20A8sub20] ParameterName=Position Loop Output Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=200 PDOMapping=1 [20A8sub21] ParameterName=Large Deviation Detection Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=600 PDOMapping=1 [20A8sub22] ParameterName=Large Deviation Detection Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=5000 DefaultValue=100 PDOMapping=1 [20A8sub23] ParameterName=Speed/Position Synchronization Switchover Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20A8sub24] ParameterName=Speed/Position Synchronization Switchover Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20A8sub25] ParameterName=Communication Delay Compensation Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20A8sub26] ParameterName=Communication Delay Setting ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=20000 DefaultValue=156 PDOMapping=1 [20A8sub27] ParameterName=element 39 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub28] ParameterName=Frequency 1 for Position Loop Proportional Gain Switchover ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=500 PDOMapping=1 [20A8sub29] ParameterName=Frequency 2 for Position Loop Proportional Gain Switchover ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=1000 PDOMapping=1 [20A8sub2A] ParameterName=element 42 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub2B] ParameterName=element 43 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub2C] ParameterName=element 44 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub2D] ParameterName=element 45 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub2E] ParameterName=element 46 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub2F] ParameterName=element 47 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub30] ParameterName=element 48 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub31] ParameterName=element 49 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub32] ParameterName=element 50 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub33] ParameterName=Master/Slave Selection in Load Allocation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20A8sub34] ParameterName=element 52 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub35] ParameterName=Station Number of Master for Synchronization (set for Slave) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=127 DefaultValue=1 PDOMapping=1 [20A8sub36] ParameterName=element 54 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub37] ParameterName=Slave Configuration Parameter (Load Allocation) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20A8sub38] ParameterName=Torque Acceleration Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=0 PDOMapping=1 [20A8sub39] ParameterName=Torque Deceleration Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=0 PDOMapping=1 [20A8sub3A] ParameterName=Frequency Gain ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20A8sub3B] ParameterName=Frequency Offset ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-10000 HighLimit=10000 DefaultValue=0 PDOMapping=1 [20A8sub3C] ParameterName=Torque Gain ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20A8sub3D] ParameterName=Torque Offset ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-10000 HighLimit=10000 DefaultValue=0 PDOMapping=1 [20A8sub3E] ParameterName=Master Sending Frequency Setting Channel Selection(set for Master) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20A8sub3F] ParameterName=Master Sending Frequency Switchover Threshold ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=500 PDOMapping=1 [20A8sub40] ParameterName=element 64 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub41] ParameterName=element 65 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub42] ParameterName=element 66 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub43] ParameterName=element 67 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub44] ParameterName=element 68 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub45] ParameterName=element 69 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub46] ParameterName=element 70 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub47] ParameterName=Master/Slave Selection in Droop Control ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20A8sub48] ParameterName=Droop Control Mode Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=2 DefaultValue=2 PDOMapping=1 [20A8sub49] ParameterName=Synchronization Master Station Number (effective for Slave) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=124 DefaultValue=1 PDOMapping=1 [20A8sub4A] ParameterName=element 74 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub4B] ParameterName=Slave Configuration Parameter (droop control) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20A8sub4C] ParameterName=element 76 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub4D] ParameterName=element 77 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub4E] ParameterName=Droop Ratio ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=1 [20A8sub4F] ParameterName=element 79 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub50] ParameterName=element 80 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub51] ParameterName=element 81 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub52] ParameterName=element 82 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub53] ParameterName=element 83 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub54] ParameterName=element 84 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub55] ParameterName=element 85 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub56] ParameterName=element 86 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub57] ParameterName=element 87 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub58] ParameterName=element 88 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub59] ParameterName=element 89 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub5A] ParameterName=element 90 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub5B] ParameterName=element 91 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub5C] ParameterName=element 92 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub5D] ParameterName=element 93 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub5E] ParameterName=element 94 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub5F] ParameterName=element 95 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub60] ParameterName=element 96 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub61] ParameterName=element 97 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub62] ParameterName=element 98 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub63] ParameterName=element 99 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A8sub64] ParameterName=element 100 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9] ParameterName=Vector Control Parameters ObjectType=9 SubNumber=37 [20A9sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=38 PDOMapping=0 [20A9sub1] ParameterName=Online Auto-tuning of Asynchronous Motor Rotor Time Constant ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 PDOMapping=1 [20A9sub2] ParameterName=Rotor Resistance Gain by Asychronous Motor Autotuning in FVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=5 PDOMapping=1 [20A9sub3] ParameterName=Start Frequency for Auto-tuning of Asynchronous Motor Rotor Resistance in FVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=2 HighLimit=100 DefaultValue=4 PDOMapping=1 [20A9sub4] ParameterName=Magnetic Field Coefficient by Auto-tuning of Asynchronous Motor in FVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=30 HighLimit=150 DefaultValue=40 PDOMapping=1 [20A9sub5] ParameterName=Maximum Torque Limit Coefficient of Weaken Flux Field in SVC/FVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=30 HighLimit=150 DefaultValue=80 PDOMapping=1 [20A9sub6] ParameterName=Speed Filter of Asynchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=5 HighLimit=32 DefaultValue=15 PDOMapping=1 [20A9sub7] ParameterName=Speed Feedback Operation of Asynchronous Motor Speed Control in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20A9sub8] ParameterName=Magnetic Field Adjusting Band of Asynchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=80 DefaultValue=20 PDOMapping=1 [20A9sub9] ParameterName=Current at Low-speed Running of Asynchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=30 HighLimit=170 DefaultValue=100 PDOMapping=1 [20A9subA] ParameterName=Switchover Frequency of Fixed Current Output of Asynchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=20 HighLimit=1000 DefaultValue=30 PDOMapping=1 [20A9subB] ParameterName=Speed Fluctuation Suppression Coefficient of Asynchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=6 DefaultValue=3 PDOMapping=1 [20A9subC] ParameterName=Acceleration/Deceleration Time of Asynchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=30000 DefaultValue=200 PDOMapping=1 [20A9subD] ParameterName=Quick Auto-tuning of Stator Resistance before Asynchronous Motor Startup ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20A9subE] ParameterName=Stator Resistance Coefficient 1 by Asynchronous Motor Quick Auto-tuning ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=10 PDOMapping=1 [20A9subF] ParameterName=Stator Resistance Coefficient 2 by Asynchronous Motor Quick Auto-tuning ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=10 PDOMapping=1 [20A9sub10] ParameterName=Stator Resistance Coefficient 3 by Asynchronous Motor Quick Auto-tuning ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20A9sub11] ParameterName=element 17 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9sub12] ParameterName=Real-time Angle of Synchronous Motor ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20A9sub13] ParameterName=Detection of Synchronous Motor Initial Angle ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20A9sub14] ParameterName=element 20 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9sub15] ParameterName=Weaken Flux Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=1 PDOMapping=1 [20A9sub16] ParameterName=Weaken Flux Gain of Synchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=50 DefaultValue=5 PDOMapping=1 [20A9sub17] ParameterName=Output Voltage Limit Margin of Synchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=50 DefaultValue=5 PDOMapping=1 [20A9sub18] ParameterName=Maximum Force Gain of Synchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=20 HighLimit=300 DefaultValue=100 PDOMapping=1 [20A9sub19] ParameterName=Excitation Current Gain of Synchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=40 HighLimit=200 DefaultValue=100 PDOMapping=1 [20A9sub1A] ParameterName=Speed Evaluation Integral Gain of Synchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=5 HighLimit=1000 DefaultValue=30 PDOMapping=1 [20A9sub1B] ParameterName=Speed Evaluation Proportional Gain of Synchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=5 HighLimit=300 DefaultValue=20 PDOMapping=1 [20A9sub1C] ParameterName=Speed Filter of Synchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=10 HighLimit=2000 DefaultValue=100 PDOMapping=1 [20A9sub1D] ParameterName=Minimum Carrier Frequency of Synchronous Motor in SVC Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=8 HighLimit=65535 DefaultValue=20 PDOMapping=1 [20A9sub1E] ParameterName=Synchronous Motor low-speed Excitation Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=80 DefaultValue=30 PDOMapping=1 [20A9sub1F] ParameterName=element 31 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9sub20] ParameterName=element 32 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9sub21] ParameterName=element 33 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9sub22] ParameterName=element 34 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9sub23] ParameterName=element 35 ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20A9sub26] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=0 [20F0] ParameterName=Basic Function ObjectType=9 SubNumber=30 [20F0sub0] ParameterName=Number of entries ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x1D PDOMapping=0 [20F0sub1] ParameterName=Inverter GP Type Display ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=1 HighLimit=2 PDOMapping=1 [20F0sub2] ParameterName=Motor Control Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F0sub3] ParameterName=Command Source ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F0sub4] ParameterName=Main Frequency Source X ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10 DefaultValue=0 PDOMapping=1 [20F0sub5] ParameterName=Auxiliary Frequency Source Y ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10 DefaultValue=0 PDOMapping=1 [20F0sub6] ParameterName=Auxiliary Frequency Source Y Range Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F0sub7] ParameterName=Auxiliary Frequency Source Y Range ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=150 DefaultValue=100 PDOMapping=1 [20F0sub8] ParameterName=Frequency Source Overlying Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=44 DefaultValue=0 PDOMapping=1 [20F0sub9] ParameterName=Pre-Set Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20F0subA] ParameterName=Run Direction ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F0subB] ParameterName=Maximal Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=5000 HighLimit=60000 DefaultValue=5000 PDOMapping=1 [20F0subC] ParameterName=Upper Limit Frequency Source ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=6 DefaultValue=0 PDOMapping=1 [20F0subD] ParameterName=Upper Limit Frequency Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20F0subE] ParameterName=Upper Limit Frequency Offset ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F0subF] ParameterName=Lower Limit Frequency Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F0sub10] ParameterName=Carrier Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=8 HighLimit=120 PDOMapping=1 [20F0sub11] ParameterName=Carrier Frequency changes as Temperature ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20F0sub12] ParameterName=Accelerate Time 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=200 PDOMapping=1 [20F0sub13] ParameterName=Decelerate Time 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=200 PDOMapping=1 [20F0sub14] ParameterName=Time Unit of Accelerate and Decelerate Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=1 PDOMapping=1 [20F0sub15] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F0sub16] ParameterName=Auxiliary Freq-Source Offset Frequency at Overlying ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F0sub17] ParameterName=Frequency Point ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=2 DefaultValue=2 PDOMapping=1 [20F0sub18] ParameterName=Frequency Set-Value Remember Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F0sub19] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F0sub1A] ParameterName=Benchmark Frequency of Accelerate and Decelerate Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F0sub1B] ParameterName=Freq-Command Up/Down Benchmark at Run ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F0sub1C] ParameterName=Main Frequency X Coefficient ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=1000 PDOMapping=1 [20F0sub1D] ParameterName=Auxiliary Frequency Y Coefficient ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=1000 PDOMapping=1 [20F1] ParameterName=Motor Parameter ObjectType=9 SubNumber=39 [20F1sub0] ParameterName=Number of entries ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x26 PDOMapping=0 [20F1sub1] ParameterName=Motor Type ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F1sub2] ParameterName=Rating Power ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=10000 PDOMapping=1 [20F1sub3] ParameterName=Rating Voltage ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=2000 PDOMapping=1 [20F1sub4] ParameterName=Rating Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub5] ParameterName=Rating Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub6] ParameterName=Rating Speed ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub7] ParameterName=Stator Resistance of Asynchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub8] ParameterName=Rotor Resistance of Asynchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub9] ParameterName=Leakage Inductance of Asynchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1subA] ParameterName=Mutual Inductance of Asynchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1subB] ParameterName=Zero Load Current of Asynchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1subC] ParameterName=Iron-core Saturation Coefficient 1 of Asyn-Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=500 HighLimit=1000 DefaultValue=860 PDOMapping=1 [20F1subD] ParameterName=Iron-core Saturation Coefficient 2 of Asyn-Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1000 HighLimit=1500 DefaultValue=1300 PDOMapping=1 [20F1subE] ParameterName=Iron-core Saturation Coefficient 3 of Asyn-Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1000 HighLimit=1700 DefaultValue=1400 PDOMapping=1 [20F1subF] ParameterName=Iron-core Saturation Coefficient 4 of Asyn-Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1000 HighLimit=1800 DefaultValue=1500 PDOMapping=1 [20F1sub10] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F1sub11] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F1sub12] ParameterName=d-axis Inductance of Synchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub13] ParameterName=q-axis Inductance of Synchronous Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub14] ParameterName=Back Elektromotive Force Coefficient of Syn-Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 PDOMapping=1 [20F1sub15] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F1sub16] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F1sub17] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F1sub18] ParameterName=Friction Moment Percentage ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=0 PDOMapping=1 [20F1sub19] ParameterName=Encoder Feedback Speed Filter(U0-29) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F1sub1A] ParameterName=PG Card Power ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20F1sub1B] ParameterName=Tuning Direction ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20F1sub1C] ParameterName=Encoder Line Number ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=20000 DefaultValue=1024 PDOMapping=1 [20F1sub1D] ParameterName=Encoder Type ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F1sub1E] ParameterName=PG Signal Filter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=1 PDOMapping=1 [20F1sub1F] ParameterName=Encoder Wiring Direction ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=1 [20F1sub20] ParameterName=Zero Point Angle of Encoder ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3599 DefaultValue=0 PDOMapping=1 [20F1sub21] ParameterName=Numerator of Motor Gear Ratio ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1 PDOMapping=1 [20F1sub22] ParameterName=Denominator of Motor Gear Ratio ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1 PDOMapping=1 [20F1sub23] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=32 DefaultValue=1 PDOMapping=0 [20F1sub24] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=0 [20F1sub25] ParameterName=PG break Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=11 DefaultValue=1 PDOMapping=1 [20F1sub26] ParameterName=Tuning Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=14 DefaultValue=0 PDOMapping=1 [20F2] ParameterName=Vector Ctrl Para ObjectType=9 SubNumber=46 [20F2sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x37 PDOMapping=0 [20F2sub1] ParameterName=Speed-loop Proportional Gain 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=200 DefaultValue=30 PDOMapping=1 [20F2sub2] ParameterName=Speed-loop Integral Time 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=10000 DefaultValue=500 PDOMapping=1 [20F2sub3] ParameterName=Switchover Frq 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=500 PDOMapping=1 [20F2sub4] ParameterName=Speed-loop Proportional Gain 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=200 DefaultValue=20 PDOMapping=1 [20F2sub5] ParameterName=Speed-loop Integral Time 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=10000 DefaultValue=1000 PDOMapping=1 [20F2sub6] ParameterName=Switchover Frq 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=1000 PDOMapping=1 [20F2sub7] ParameterName=Vector Ctrl Slip Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=50 HighLimit=200 DefaultValue=100 PDOMapping=1 [20F2sub8] ParameterName=Time Const of Speed-loop Filter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=4 PDOMapping=1 [20F2sub9] ParameterName=Vector Ctrl Over-excitation Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=200 DefaultValue=64 PDOMapping=1 [20F2subA] ParameterName=Torque Upper-limit Source (Spd Ctrl Mode) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=7 DefaultValue=0 PDOMapping=1 [20F2subB] ParameterName=Digital Setting of Torque upper limit (Spd Ctrl Mode) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2000 DefaultValue=1500 PDOMapping=1 [20F2subC] ParameterName=NegTorqueLimitSrc ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=8 DefaultValue=0 PDOMapping=1 [20F2subD] ParameterName=NegTorqueLimit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2000 DefaultValue=1500 PDOMapping=1 [20F2subE] ParameterName=Low Speed Current Loop Kp ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=10 PDOMapping=1 [20F2subF] ParameterName=Low Speed Current Loop Ki ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=10 PDOMapping=1 [20F2sub10] ParameterName=High Speed Current Loop Kp ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=10 PDOMapping=1 [20F2sub11] ParameterName=High Speed Current Loop Ki ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=10 PDOMapping=1 [20F2sub12] ParameterName=Zero-speed Lock Speed-loop Kp ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=30 PDOMapping=1 [20F2sub13] ParameterName=Zero-speed Lock Speed-loop Ki ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=10000 DefaultValue=500 PDOMapping=1 [20F2sub15] ParameterName=Zero-speed Lock Speed-loop Switch Frq ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5 PDOMapping=1 [20F2sub16] ParameterName=Max Output-voltage Coefficient ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=100 HighLimit=110 DefaultValue=100 PDOMapping=1 [20F2sub17] ParameterName=Filtering Time of Output-voltage ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10 DefaultValue=0 PDOMapping=1 [20F2sub18] ParameterName=Zero Speed Lock Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F2sub19] ParameterName=Vector Overvoltage Suppresion KP ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=40 PDOMapping=1 [20F2sub1A] ParameterName=Gain of Acceleration Compensation ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=200 DefaultValue=0 PDOMapping=1 [20F2sub1B] ParameterName=Filtering Time of Acceleration Compensation ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=500 DefaultValue=10 PDOMapping=1 [20F2sub1C] ParameterName=Vector Overvoltage Suppresion Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20F2sub1D] ParameterName=Torque Filter Cutoff Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=50 HighLimit=1000 DefaultValue=500 PDOMapping=1 [20F2sub1E] ParameterName=Initial Position Angle Detecting Current of Syn-Motor ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=50 HighLimit=180 DefaultValue=80 PDOMapping=1 [20F2sub1F] ParameterName=Enable Automatic Caculation for Speed-loop Parameter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F2sub20] ParameterName=Expectation of Speed-loop Bandwidth(High-speed) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=10 HighLimit=2000 DefaultValue=100 PDOMapping=1 [20F2sub21] ParameterName=Expectation of Speed-loop Bandwidth(Low-speed) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=10 HighLimit=2000 DefaultValue=100 PDOMapping=1 [20F2sub22] ParameterName=Expectation of Speed-loop Bandwidth(Zero-speed) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=10 HighLimit=2000 DefaultValue=100 PDOMapping=1 [20F2sub23] ParameterName=Expectation of Speed-loop Damping Ratio ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=100 HighLimit=65000 DefaultValue=1000 PDOMapping=1 [20F2sub24] ParameterName=System Inertia Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=50000 PDOMapping=1 [20F2sub25] ParameterName=Motor Inertia Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=50000 PDOMapping=1 [20F2sub2C] ParameterName=SpeedRgTunePeakFreq ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=30 PDOMapping=1 [20F2sub30] ParameterName=InertiaTuneEnable ObjectType=7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=1 [20F2sub31] ParameterName=InertiaTuneBw ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20F2sub32] ParameterName=InertiaTuneDir ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=0 [20F2sub33] ParameterName=InertiaTuneMode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F2sub34] ParameterName=InertiaTuneAdj ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=10 PDOMapping=1 [20F2sub35] ParameterName=DeCouplingEn ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F2sub36] ParameterName=Power Limit for Power Generation Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F2sub37] ParameterName=Power Limit for Power Generation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2000 PDOMapping=1 [20F3] ParameterName=V/F Control Parameter ObjectType=9 SubNumber=35 [20F3sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x22 PDOMapping=0 [20F3sub1] ParameterName=V/F Curve Setting ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=11 DefaultValue=0 PDOMapping=1 [20F3sub2] ParameterName=Torque Boost ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=300 PDOMapping=1 [20F3sub3] ParameterName=Cut-off Frq of Torque Boost ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20F3sub4] ParameterName=Multi-Point V/F Frq 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F3sub5] ParameterName=Multi-Piont V/F Voltage 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F3sub6] ParameterName=Multi-Point V/F Frq 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F3sub7] ParameterName=Multi-Point V/F Voltage 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F3sub8] ParameterName=Multi-Point V/F Frq 3 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F3sub9] ParameterName=Multi-Point V/F Voltage 3 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F3subA] ParameterName=V/F Slip Compensation Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2000 DefaultValue=0 PDOMapping=1 [20F3subB] ParameterName=V/F Over-Excitation Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=200 DefaultValue=64 PDOMapping=1 [20F3subC] ParameterName=V/F Oscillation Suppression Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 PDOMapping=1 [20F3subD] ParameterName=V/F Oscillation Suppression Mode Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=3 PDOMapping=1 [20F3subE] ParameterName=Voltage Source for V/F Separation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=8 DefaultValue=0 PDOMapping=1 [20F3subF] ParameterName=Digital Setting of Voltage for V/F Separation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F3sub10] ParameterName=Voltage Rise Time of V/F Separation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=0 PDOMapping=1 [20F3sub11] ParameterName=Voltage Decline Time of V/F Separation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=0 PDOMapping=1 [20F3sub12] ParameterName=Stop Mode Selection for V/F Separation ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F3sub13] ParameterName=V/F Over Current Limit Point ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=50 HighLimit=200 DefaultValue=150 PDOMapping=1 [20F3sub14] ParameterName=V/F Over Current Limit Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20F3sub15] ParameterName=V/F Over Current Limit Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=20 PDOMapping=1 [20F3sub16] ParameterName=V/F Compensation Factor of Speed Multiplying Current Limit Level ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=50 HighLimit=200 DefaultValue=50 PDOMapping=1 [20F3sub17] ParameterName=V/F Over Voltage Limit Point ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=6500 HighLimit=8000 DefaultValue=7700 PDOMapping=1 [20F3sub18] ParameterName=V/F Over Voltage Limit Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20F3sub19] ParameterName=V/F Frequency Gain for Over Voltage Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=30 PDOMapping=1 [20F3sub1A] ParameterName=V/F Voltage Gain for Over Voltage Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=30 PDOMapping=1 [20F3sub1B] ParameterName=Frequency Rise Threshold during Over Voltage Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=50 DefaultValue=5 PDOMapping=1 [20F3sub1C] ParameterName=Slip Compensation Time Constant ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=5 PDOMapping=1 [20F3sub1D] ParameterName=Auto Frequency Boost Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F3sub1E] ParameterName=Minimum Torque Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=10 HighLimit=100 DefaultValue=50 PDOMapping=1 [20F3sub1F] ParameterName=Maximum Torque Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=10 HighLimit=100 DefaultValue=20 PDOMapping=1 [20F3sub20] ParameterName=Auto Frequency Boost KP ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=50 PDOMapping=1 [20F3sub21] ParameterName=Auto Frequency Boost KI ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=50 PDOMapping=1 [20F3sub22] ParameterName=Online Torque Compensation Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=80 HighLimit=150 DefaultValue=100 PDOMapping=1 [20F4] ParameterName=Input Terminals ObjectType=9 SubNumber=36 [20F4sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x2A PDOMapping=0 [20F4sub1] ParameterName=DI1 Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=1 PDOMapping=1 [20F4sub2] ParameterName=DI2Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=4 PDOMapping=1 [20F4sub3] ParameterName=DI3 Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=9 PDOMapping=1 [20F4sub4] ParameterName=DIO1 Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=12 PDOMapping=1 [20F4sub5] ParameterName=DIO2 Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=63 DefaultValue=13 PDOMapping=1 [20F4subB] ParameterName=DI Filter Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=10 PDOMapping=1 [20F4subC] ParameterName=DI Control Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20F4subD] ParameterName=DI Up/Down Slope ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1000 PDOMapping=1 [20F4subE] ParameterName=AI1 min. Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=32767 DefaultValue=-1000 PDOMapping=1 [20F4subF] ParameterName=AI1 min. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=-1000 PDOMapping=1 [20F4sub10] ParameterName=AI1 max. Input ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F4sub11] ParameterName=AI1 max. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F4sub12] ParameterName=AI1 Filter Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=10 PDOMapping=1 [20F4sub13] ParameterName=AI2 min. Input ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F4sub14] ParameterName=AI2 min. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F4sub15] ParameterName=AI2 max. Input ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F4sub16] ParameterName=AI2 max. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F4sub17] ParameterName=AI2 Filter Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=10 PDOMapping=1 [20F4sub18] ParameterName=AI3 min. Input ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=-1000 PDOMapping=1 [20F4sub19] ParameterName=AI3 min. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=-1000 PDOMapping=1 [20F4sub1A] ParameterName=AI3 max. Input ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F4sub1B] ParameterName=AI3 max. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F4sub1D] ParameterName=Pulse min. Input ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F4sub1E] ParameterName=Pulse min. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 PDOMapping=1 [20F4sub1F] ParameterName=Pulse max. Input ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=5000 PDOMapping=1 [20F4sub20] ParameterName=Pulse max. Input Equivalent Value ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F4sub21] ParameterName=Pulse Filter Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=10 PDOMapping=1 [20F4sub22] ParameterName=AI Curve Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=555 DefaultValue=0x321 PDOMapping=1 [20F4sub23] ParameterName=Input Selection when AI below than min. Input ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=111 DefaultValue=0 PDOMapping=1 [20F4sub24] ParameterName=DI1 Delay Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=36000 DefaultValue=0 PDOMapping=1 [20F4sub25] ParameterName=DI2 Delay Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=36000 DefaultValue=0 PDOMapping=1 [20F4sub26] ParameterName=DI3 Delay Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=36000 DefaultValue=0 PDOMapping=1 [20F4sub27] ParameterName=Valid State Selection for DI Terminal ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=11111 DefaultValue=0 PDOMapping=1 [20F4sub29] ParameterName=AI2 Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F4sub2A] ParameterName=DIO Terminal Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F5] ParameterName=Output Terminals ObjectType=9 SubNumber=15 [20F5sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x18 PDOMapping=0 [20F5sub1] ParameterName=FM Terminal Output Mode Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F5sub2] ParameterName=FMR Output Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=40 DefaultValue=0 PDOMapping=1 [20F5sub3] ParameterName=Relay Funtion Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=40 DefaultValue=2 PDOMapping=1 [20F5sub5] ParameterName=DO1 Output Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=40 DefaultValue=0 PDOMapping=1 [20F5sub7] ParameterName=FMP Output Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=19 DefaultValue=0 PDOMapping=1 [20F5sub8] ParameterName=AO1 Output Function Selection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=19 DefaultValue=0 PDOMapping=1 [20F5subA] ParameterName=FMP Output max. Frequence ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=10000 DefaultValue=5000 PDOMapping=1 [20F5subB] ParameterName=AO1 Offset Factor ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F5subC] ParameterName=AO1 Gain ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20F5sub12] ParameterName=FMR Output Delay Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=36000 DefaultValue=0 PDOMapping=1 [20F5sub13] ParameterName=Relay Output Delay Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F5sub15] ParameterName=DO1 Output Delay Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=36000 DefaultValue=0 PDOMapping=1 [20F5sub17] ParameterName=Valid State Selection for DO Terminal ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=11111 DefaultValue=0 PDOMapping=1 [20F5sub18] ParameterName=AO1 Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F6] ParameterName=Start-Stop Control ObjectType=9 SubNumber=26 [20F6sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x1A PDOMapping=0 [20F6sub1] ParameterName=Start Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F6sub2] ParameterName=Speed Tracking Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F6sub3] ParameterName=Speed Tracking Rate ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=100 DefaultValue=20 PDOMapping=1 [20F6sub4] ParameterName=Start Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F6sub5] ParameterName=Start Frequency Keep Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F6sub6] ParameterName=Start DC Brake Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=0 PDOMapping=1 [20F6sub7] ParameterName=Start DC Brake Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F6sub8] ParameterName=Acceleration and Deceleration Method ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F6sub9] ParameterName=S-Curve Start Phase Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=300 PDOMapping=1 [20F6subA] ParameterName=S-Curve End Phase Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=300 PDOMapping=1 [20F6subB] ParameterName=Stop Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F6subC] ParameterName=Stop DC Brake Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F6subD] ParameterName=Stop DC Brake Wait Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F6subE] ParameterName=Stop DC Brake Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=0 PDOMapping=1 [20F6subF] ParameterName=Stop DC Brake Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F6sub10] ParameterName=Brake Duty Ratio ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=100 PDOMapping=1 [20F6sub11] ParameterName=Speed Tracking Closed-loop Current KP ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=500 PDOMapping=1 [20F6sub12] ParameterName=Speed Tracking Closed-loop Current KI ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=800 PDOMapping=1 [20F6sub13] ParameterName=Speed Tracking Closed-loop Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=30 HighLimit=200 DefaultValue=100 PDOMapping=1 [20F6sub15] ParameterName=Speed Tracking Voltage Up Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=5 HighLimit=30 DefaultValue=10 PDOMapping=1 [20F6sub16] ParameterName=Demagnetizing Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20F6sub17] ParameterName=Start Torque ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2000 DefaultValue=0 PDOMapping=1 [20F6sub18] ParameterName=Rectifier Command Set ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F6sub19] ParameterName=Zero Servo KP ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20F6sub1A] ParameterName=Zero Servo End Amplitude ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=16383 DefaultValue=10 PDOMapping=1 [20F7] ParameterName=Keypad and Display ObjectType=9 SubNumber=15 [20F7sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x11 PDOMapping=0 [20F7sub4] ParameterName=Run Led Display Parameter 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=0xFFFF DefaultValue=0x001F PDOMapping=1 [20F7sub5] ParameterName=Run Led Display Parameter 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F7sub6] ParameterName=Stop Led Display Parameter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0x0033 PDOMapping=1 [20F7sub7] ParameterName=Speed Display Coefficient ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65000 DefaultValue=10000 PDOMapping=1 [20F7sub8] ParameterName=Rediator Tempratur ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=1000 PDOMapping=1 [20F7sub9] ParameterName=Product Version ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=1000 PDOMapping=1 [20F7subA] ParameterName=Accumulated Run Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 PDOMapping=1 [20F7subB] ParameterName=Core Software Version ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F7subC] ParameterName=Func Software Version ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F7subD] ParameterName=Speed Display Point Position ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=1 PDOMapping=1 [20F7subE] ParameterName=Accumulated Power-Up Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 PDOMapping=1 [20F7subF] ParameterName=Accumulated Power Consumption ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F7sub10] ParameterName=Core Temp Software Version ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F7sub11] ParameterName=Func Temp Software Version ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F8] ParameterName=Auxiliary Functions ObjectType=9 SubNumber=55 [20F8sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x39 PDOMapping=0 [20F8sub1] ParameterName=Jog Running Frequence ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=200 PDOMapping=1 [20F8sub2] ParameterName=Jog Accelerate Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=200 PDOMapping=1 [20F8sub3] ParameterName=Jog Decelerate Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=200 PDOMapping=1 [20F8sub4] ParameterName=Accelerate Time 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 PDOMapping=1 [20F8sub5] ParameterName=Decelerate Time 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 PDOMapping=1 [20F8sub6] ParameterName=Accelerate Time 3 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 PDOMapping=1 [20F8sub7] ParameterName=Decelerate Time 3 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 PDOMapping=1 [20F8sub8] ParameterName=Accelerate Time 4 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 PDOMapping=1 [20F8sub9] ParameterName=Decelerate Time 4 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 PDOMapping=1 [20F8subA] ParameterName=Jump Frequency 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F8subB] ParameterName=Jump Frequency 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F8subC] ParameterName=Jump Frequence Amplitude ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F8subD] ParameterName=Zero Speed Dead Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=30000 DefaultValue=0 PDOMapping=1 [20F8subE] ParameterName=Reverse Run enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F8subF] ParameterName=Run Mode at Frequency below than low limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F8sub11] ParameterName=Set Accumulated Power-up Arrival Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20F8sub12] ParameterName=Set Accumulated Run Arrival Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20F8sub13] ParameterName=Start Protect ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F8sub14] ParameterName=Frequency Detection Value(FDT1) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20F8sub15] ParameterName=Frequency Detection Lag(FDT1) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=50 PDOMapping=1 [20F8sub16] ParameterName=Frequency Arrival Detection Range ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F8sub17] ParameterName=Enable Jump Frequency during Accelerate and Decelerate ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F8sub1A] ParameterName=Accelerate Time 1/2 Frequency Change Point ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F8sub1B] ParameterName=Decelerate Time 1/2 Frequency Change Point ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F8sub1C] ParameterName=Priority for Jog ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F8sub1D] ParameterName=Frequency Detection Value(FDT2) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20F8sub1E] ParameterName=Frequency Detection Lag(FDT2) ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=50 PDOMapping=1 [20F8sub1F] ParameterName=Any Arrival Frequency Detection Value 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20F8sub20] ParameterName=Any Arrival Frequency Detection Range 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F8sub21] ParameterName=Any Arrival Frequency Detection Value 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5000 PDOMapping=1 [20F8sub22] ParameterName=Any Arrival Frequency Detection Range 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20F8sub23] ParameterName=Zero Current Detection Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3000 DefaultValue=50 PDOMapping=1 [20F8sub24] ParameterName=Zero Current Detection Lag Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=60000 DefaultValue=10 PDOMapping=1 [20F8sub25] ParameterName=Over-limit Value of Output Current ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3000 DefaultValue=2000 PDOMapping=1 [20F8sub26] ParameterName=Lag Time of Software Over-current Detection ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=60000 DefaultValue=0 PDOMapping=1 [20F8sub27] ParameterName=Any Arrival Current 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3000 DefaultValue=1000 PDOMapping=1 [20F8sub28] ParameterName=Any Arrival Current Range 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3000 DefaultValue=0 PDOMapping=1 [20F8sub29] ParameterName=Any Arrival Current 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3000 DefaultValue=1000 PDOMapping=1 [20F8sub2A] ParameterName=Any Arrival Current Range 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3000 DefaultValue=0 PDOMapping=1 [20F8sub2B] ParameterName=Timing Funtion Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F8sub2C] ParameterName=Timing of Run Time Select ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20F8sub2D] ParameterName=Timing of Run Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20F8sub2E] ParameterName=Low Limit of AI1 Input Voltage Protection Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=310 PDOMapping=1 [20F8sub2F] ParameterName=High Limit of AI1 Input Voltage Protection Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=680 PDOMapping=1 [20F8sub30] ParameterName=Temperature Arrive ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=75 PDOMapping=1 [20F8sub31] ParameterName=Radiator Fan Control ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F8sub32] ParameterName=Wake Up Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F8sub33] ParameterName=Wake Up Lag Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20F8sub34] ParameterName=Dormant Frequency ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20F8sub35] ParameterName=Dormant Lag Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20F8sub36] ParameterName=Actual Run Arrival Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20F8sub37] ParameterName=STO Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F8sub38] ParameterName=Decelerate Time of Emergency Stop ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20F8sub39] ParameterName=LED Keyboard Jog Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=0 DefaultValue=0 PDOMapping=1 [20F9] ParameterName=Fault and Protection ObjectType=9 SubNumber=67 [20F9sub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x4A PDOMapping=0 [20F9sub1] ParameterName=Converter Overload Inhibition Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F9sub2] ParameterName=Electric Motor Overload Protection Gain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=20 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20F9sub3] ParameterName=Electric Motor Overload Warning Coeffecient ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=50 HighLimit=100 DefaultValue=80 PDOMapping=1 [20F9sub7] ParameterName=Output Phase Lose Detection before Start ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F9sub8] ParameterName=Software Ground Short Circurt Detection Select ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=3 DefaultValue=1 PDOMapping=1 [20F9subA] ParameterName=Number of Times for Error Self-Reset ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=20 DefaultValue=0 PDOMapping=1 [20F9subB] ParameterName=Error DO Act Select during Error Self-Reset ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20F9subC] ParameterName=Space Time for Error Self-Reset ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=1000 DefaultValue=10 PDOMapping=1 [20F9subD] ParameterName=Hardware Ground Short Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=1 PDOMapping=1 [20F9subF] ParameterName=Error Type for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=99 PDOMapping=1 [20F9sub10] ParameterName=Error Type for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=99 PDOMapping=1 [20F9sub11] ParameterName=Error Type for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=99 PDOMapping=1 [20F9sub12] ParameterName=Frequency on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub13] ParameterName=Current on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub14] ParameterName=Bus Voltage on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub15] ParameterName=Input Terminal State on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub16] ParameterName=Output Terminal State on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub17] ParameterName=Converter State on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub18] ParameterName=Time from Power-up on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub19] ParameterName=Time from Run on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub1A] ParameterName=IGBT Temperatur on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub1B] ParameterName=Error Sub-Code on Error for the Third Time(Last Time) ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub1C] ParameterName=Frequency on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub1D] ParameterName=Current on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub1E] ParameterName=Bus Voltage on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub1F] ParameterName=Input Terminal State on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub20] ParameterName=Output Terminal State on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub21] ParameterName=Converter State on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub22] ParameterName=Time from Power-up on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub23] ParameterName=Time from Run on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub24] ParameterName=IGBT Temperatur on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub25] ParameterName=Error Sub-Code on Error for the Second Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub26] ParameterName=Frequency on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub27] ParameterName=Current on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub28] ParameterName=Bus Voltage on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub29] ParameterName=Input Terminal State on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub2A] ParameterName=Output Terminal State on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub2B] ParameterName=Converter State on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub2C] ParameterName=Time from Power-up on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub2D] ParameterName=Time from Run on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub2E] ParameterName=IGBT Temperatur on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub2F] ParameterName=Error Sub-Code on Error for the First Time ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=0 PDOMapping=1 [20F9sub31] ParameterName=Error Protection Action Select 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=10050 PDOMapping=1 [20F9sub32] ParameterName=Error Protection Action Select 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=50 PDOMapping=1 [20F9sub33] ParameterName=Error Protection Action Select 3 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=25000 PDOMapping=1 [20F9sub34] ParameterName=Error Protection Action Select 4 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=51111 PDOMapping=1 [20F9sub35] ParameterName=Error Protection Action Select 5 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=101 PDOMapping=1 [20F9sub36] ParameterName=Error Protection Action Select 6 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=5500 PDOMapping=1 [20F9sub37] ParameterName=Frequency Select for Keep-Run on Error ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=4 DefaultValue=1 PDOMapping=1 [20F9sub38] ParameterName=Backup Frequency on Error ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=600 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20F9sub39] ParameterName=Sensor Type of Motor Temperatur ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F9sub3A] ParameterName=Motor Overheat Protection Threshold ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=200 DefaultValue=110 PDOMapping=1 [20F9sub3B] ParameterName=Motor Overheat Pre-Alarm Threshold ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=200 DefaultValue=90 PDOMapping=1 [20F9sub3C] ParameterName=Instantaneous Stop Action ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20F9sub3D] ParameterName=pOffTransitoryFrqDecSlope ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=80 HighLimit=100 DefaultValue=85 PDOMapping=1 [20F9sub3E] ParameterName=pOffVolBackTime ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=5 PDOMapping=1 [20F9sub3F] ParameterName=pOffThresholdVol ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=60 HighLimit=100 DefaultValue=80 PDOMapping=1 [20F9sub41] ParameterName=Load Lose Detection Level ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=100 PDOMapping=1 [20F9sub42] ParameterName=Load Lose Detection Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=600 DefaultValue=10 PDOMapping=1 [20F9sub44] ParameterName=Over Speed Detection Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=500 DefaultValue=50 PDOMapping=1 [20F9sub45] ParameterName=Over Speed Detection Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=600 DefaultValue=10 PDOMapping=1 [20F9sub46] ParameterName=Large Speed Deviation Detection Value ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=500 DefaultValue=200 PDOMapping=1 [20F9sub47] ParameterName=Large Speed Deviation Detection Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=600 DefaultValue=50 PDOMapping=1 [20F9sub48] ParameterName=pOffTransitoryNoStopKp ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=40 PDOMapping=1 [20F9sub49] ParameterName=pOffTransitoryNoStopKiCoff ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=100 DefaultValue=30 PDOMapping=1 [20F9sub4A] ParameterName=pOffTransitoryNoStopDecTime ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3000 DefaultValue=200 PDOMapping=1 [20FA] ParameterName=PID Func ObjectType=9 SubNumber=29 [20FAsub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro LowLimit=0 DefaultValue=0x1C PDOMapping=0 [20FAsub1] ParameterName=PID Setting Source ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=6 PDOMapping=1 [20FAsub2] ParameterName=PID Digital Setting ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=500 PDOMapping=1 [20FAsub3] ParameterName=PID Feedback Source ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=8 DefaultValue=0 PDOMapping=1 [20FAsub4] ParameterName=PID Action Dir ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20FAsub5] ParameterName=PID Setting Feedback Range ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=1000 PDOMapping=1 [20FAsub6] ParameterName=Kp1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=200 PDOMapping=1 [20FAsub7] ParameterName=Ti1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=1000 DefaultValue=200 PDOMapping=1 [20FAsub8] ParameterName=Td1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=0 PDOMapping=1 [20FAsub9] ParameterName=Cut-off Frq of PID Rev Ro ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 DefaultValue=200 PDOMapping=1 [20FAsubA] ParameterName=PID Deviation Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FAsubB] ParameterName=PID Diff Limit ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=10 PDOMapping=1 [20FAsubC] ParameterName=PID Setting Change Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 PDOMapping=1 [20FAsubD] ParameterName=PID Feedback Filter Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=6000 DefaultValue=0 PDOMapping=1 [20FAsubE] ParameterName=pidErrorGain ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=1000 PDOMapping=1 [20FAsubF] ParameterName=pidSampleTime ObjectType=7 DataType=0x0006 AccessType=rw PDOMapping=0 [20FAsub10] ParameterName=Kp2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=200 PDOMapping=1 [20FAsub11] ParameterName=Ti2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=1000 DefaultValue=200 PDOMapping=1 [20FAsub12] ParameterName=Td2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 PDOMapping=1 [20FAsub13] ParameterName=PID Para Swi Condition ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20FAsub14] ParameterName=PID Para Swi Deviation 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 DefaultValue=200 PDOMapping=1 [20FAsub15] ParameterName=PID Para Swi Deviation 2 ObjectType=7 DataType=0x0006 AccessType=rw HighLimit=1000 DefaultValue=800 PDOMapping=1 [20FAsub16] ParameterName=PID Init Val ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 PDOMapping=1 [20FAsub17] ParameterName=PID Init Val Holding T ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65000 DefaultValue=0 PDOMapping=1 [20FAsub18] ParameterName=Max devi between two PID in Forward Dir ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=100 PDOMapping=1 [20FAsub19] ParameterName=Max devi between two PID in Reverse Dir ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=10000 DefaultValue=100 PDOMapping=1 [20FAsub1A] ParameterName=PID Inte Prop ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=11 DefaultValue=0 PDOMapping=1 [20FAsub1B] ParameterName=Detction Val of PID Feedback Loss ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FAsub1C] ParameterName=Detction Time of PID Feedback Loss ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=200 DefaultValue=0 PDOMapping=1 [20FB] ParameterName=Swing Length and Counter ObjectType=9 SubNumber=12 [20FBsub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=20 PDOMapping=0 [20FBsub1] ParameterName=Swing Base Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20FBsub2] ParameterName=Swing Amplitude ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FBsub3] ParameterName=Swing Jump Frequency Range ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=500 DefaultValue=0 PDOMapping=1 [20FBsub4] ParameterName=Swing Period ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=30000 DefaultValue=100 PDOMapping=1 [20FBsub5] ParameterName=Swing Triangular Wave Rise Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=1000 DefaultValue=500 PDOMapping=1 [20FBsub6] ParameterName=Set Length ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=1000 PDOMapping=1 [20FBsub7] ParameterName=Current Length ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FBsub8] ParameterName=Number of Pulse per Meter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1000 PDOMapping=1 [20FBsub9] ParameterName=Set Counter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1000 PDOMapping=1 [20FBsubA] ParameterName=Counter Point ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=65535 DefaultValue=1000 PDOMapping=1 [20FBsub14] ParameterName=Reserved ObjectType=7 DataType=0x0006 AccessType=ro PDOMapping=0 [20FC] ParameterName=Multiple Instruction and Simple PLC ObjectType=9 SubNumber=53 [20FCsub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=52 PDOMapping=0 [20FCsub1] ParameterName=Multiple Instruction 0 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub2] ParameterName=Multiple Instruction 1 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub3] ParameterName=Multiple Instruction 2 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub4] ParameterName=Multiple Instruction 3 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub5] ParameterName=Multiple Instruction 4 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub6] ParameterName=Multiple Instruction 5 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub7] ParameterName=Multiple Instruction 6 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub8] ParameterName=Multiple Instruction 7 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub9] ParameterName=Multiple Instruction 8 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsubA] ParameterName=Multiple Instruction 9 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsubB] ParameterName=Multiple Instruction 10 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsubC] ParameterName=Multiple Instruction 11 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsubD] ParameterName=Multiple Instruction 12 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsubE] ParameterName=Multiple Instruction 13 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsubF] ParameterName=Multiple Instruction 14 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub10] ParameterName=Multiple Instruction 15 ObjectType=7 DataType=0x0003 AccessType=rw LowLimit=-1000 HighLimit=1000 DefaultValue=0 PDOMapping=1 [20FCsub11] ParameterName=Run Mode of Simple PLC ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=2 DefaultValue=0 PDOMapping=1 [20FCsub12] ParameterName=Power Down Memory Select of Simple PLC ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=11 DefaultValue=0 PDOMapping=1 [20FCsub13] ParameterName=Run Time of PLC Segment 0 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub14] ParameterName=Acceleration and Receleration Time Select of PLC Segment 0 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub15] ParameterName=Run Time of PLC Segment 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub16] ParameterName=Acceleration and Receleration Time Select of PLC Segment 1 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub17] ParameterName=Run Time of PLC Segment 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub18] ParameterName=Acceleration and Receleration Time Select of PLC Segment 2 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub19] ParameterName=Run Time of PLC Segment 3 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub1A] ParameterName=Acceleration and Receleration Time Select of PLC Segment 3 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub1B] ParameterName=Run Time of PLC Segment 4 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub1C] ParameterName=Acceleration and Receleration Time Select of PLC Segment 4 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub1D] ParameterName=Run Time of PLC Segment 5 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub1E] ParameterName=Acceleration and Receleration Time Select of PLC Segment 5 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub1F] ParameterName=Run Time of PLC Segment 6 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub20] ParameterName=Acceleration and Receleration Time Select of PLC Segment 6 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub21] ParameterName=Run Time of PLC Segment 7 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub22] ParameterName=Acceleration and Receleration Time Select of PLC Segment 7 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub23] ParameterName=Run Time of PLC Segment 8 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub24] ParameterName=Acceleration and Receleration Time Select of PLC Segment 8 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub25] ParameterName=Run Time of PLC Segment 9 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub26] ParameterName=Acceleration and Receleration Time Select of PLC Segment 9 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub27] ParameterName=Run Time of PLC Segment 10 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub28] ParameterName=Acceleration and Receleration Time Select of PLC Segment 10 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub29] ParameterName=Run Time of PLC Segment 11 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub2A] ParameterName=Acceleration and Receleration Time Select of PLC Segment 11 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub2B] ParameterName=Run Time of PLC Segment 12 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub2C] ParameterName=Acceleration and Receleration Time Select of PLC Segment 12 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub2D] ParameterName=Run Time of PLC Segment 13 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub2E] ParameterName=Acceleration and Receleration Time Select of PLC Segment 13 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub2F] ParameterName=Run Time of PLC Segment 14 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub30] ParameterName=Acceleration and Receleration Time Select of PLC Segment 14 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub31] ParameterName=Run Time of PLC Segment 15 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 DefaultValue=0 PDOMapping=1 [20FCsub32] ParameterName=Acceleration and Receleration Time Select of PLC Segment 15 ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 DefaultValue=0 PDOMapping=1 [20FCsub33] ParameterName=Unit of PLC Run Time ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 DefaultValue=0 PDOMapping=1 [20FCsub34] ParameterName=Given Mode of Muliple Instruction ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=6 DefaultValue=0 PDOMapping=1 [20FD] ParameterName=Communication Parameter ObjectType=9 SubNumber=30 [20FDsub0] ParameterName=number of elements ObjectType=7 DataType=0x0005 AccessType=ro DefaultValue=0x64 PDOMapping=0 [20FDsub1] ParameterName=Baudrate of Modbus ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=9 PDOMapping=0 [20FDsub2] ParameterName=Data Mode ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=3 PDOMapping=0 [20FDsub3] ParameterName=Station Number for Modbus ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=247 PDOMapping=0 [20FDsub4] ParameterName=Response Delay ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=20 PDOMapping=0 [20FDsub5] ParameterName=Communication Overtime ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=600 PDOMapping=0 [20FDsub7] ParameterName=Communication Error Reset Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 PDOMapping=0 [20FDsubA] ParameterName=Communication Mode ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=999 PDOMapping=0 [20FDsubB] ParameterName=Canopen/Canlink Select ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=2 PDOMapping=0 [20FDsubC] ParameterName=Canopen402 Enable ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=1 PDOMapping=0 [20FDsubD] ParameterName=CAN Baudrate ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=6 PDOMapping=0 [20FDsubE] ParameterName=CAN Station Number ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=127 PDOMapping=0 [20FDsubF] ParameterName=Number of CAN Message in a Period ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub10] ParameterName=Max. Value of Station Receive Error Counter ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub11] ParameterName=Max. Value of Stattion Send Error Counter ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub12] ParameterName=Number of CAN Bus-Off in a Period ObjectType=7 DataType=0x0006 AccessType=ro LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub13] ParameterName=Rectifier Unit Number ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=99 PDOMapping=0 [20FDsub14] ParameterName=CAN Comm-Off Parameter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=15 PDOMapping=0 [20FDsub15] ParameterName=ProfibusDP Communication Parameter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=1 HighLimit=125 PDOMapping=0 [20FDsub16] ParameterName=ProfibusDP Comm-Off Parameter ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub1F] ParameterName=Number of Bytes for RPDO1\ RPDO2 Mapping ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub20] ParameterName=Number of Bytes for TPDO1\TPDO2 Mapping ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub21] ParameterName=Mapping Mode Select ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub5E] ParameterName=Reserved Addresse for DP Bridge ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub5F] ParameterName=Modbus Software Version ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub60] ParameterName=Canlink Software Version ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub61] ParameterName=Canopen Software Version ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub62] ParameterName=DP Software Version ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub63] ParameterName=DP Bridge Software Version ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0 [20FDsub64] ParameterName=Modbus Bridge Software Version ObjectType=7 DataType=0x0006 AccessType=rw LowLimit=0 HighLimit=65535 PDOMapping=0